Scxi-1357. Finally, there is the SCXI-1355, which is a shielded cable assembly with cable lengths to 10 m. Scxi-1357

 
 Finally, there is the SCXI-1355, which is a shielded cable assembly with cable lengths to 10 mScxi-1357 ni 1357 キット(4 スロット)は次の部品で構成されてます。 • ni usb-1359 またはni scxi-1359 • ni scxi-1359 •8ピンhvab プラグ(1) • sh9md-9md ケーブル(scxi キット)またはusb ケーブル (usb キット) 図1 は、ni 1357/1358/1359 キットに含まれる部品を示します。following kits: SCXI-1357, SCXI-1358, SCXI-1359, and SCXI-1362

Each cable assembly includes a cable and one or more SCXI cable adapters. The SCXI-1357 is a High Voltage Backplane Adapter. SCP. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. We have New & Used SCXI-1357 Adapter Board by National Instruments In Stock & ready to ship! Request a fast quote or call 1-800-915-6216 now to get your price on all National. 1-slot adapters are sold separately. General. Part Number: 776575-57, 185006A-01, 185006B-01, 185008A-01, 185008B-01National Instruments 181625-01 Rear Filler Panel for SCXI-1361. To add more chassis to your high-voltage backplane configuration, purchase one add-on kit for each chassis added. 1553. The SCXI-1358 is identical to the SCXI-1357, except it is for a 12-slot SCXI chassis. The SCXI-1358 is identical to the SCXI-1357, except it is for a 12-slot SCXI chassis. We currently maintain an inventory with a wide array of components. This document explains the different scanning options, hardware setup, and programming techniques for scanning several modules. The NI USB-1357 is designed and manufactured by National Instruments. Experienced Expert Engineers that specialize in your applicationThe three available backplane kits are: SCXI-1357, SCXI-1358, and or SCXI-1359. This cable assembly routes signals from the digitizer to subsequent SCXI chassis. arincSCXI-1127/1128, SCXI-116X family, and SCXI-1190/1191. arincThen, follow the steps below: 1. NI Switches Help for more information about NI SCXI switch controllers and adapter kits. To add moreThe 185003A-01 is the 1-slot HVAB Adapter for SCXI chassis. Abstract: D412 SP400 ASTM D2240, D412 ASTM D374 D1458 D149 D150 D2240 D257 Text: Number 0. • Combination chassis for SCXI and PXI/Compact PCI modules • House all SCXI modules Assembling the system requires the use of the SCXI 1349 shielded cable assembly and the SCXI 1357 high voltage backplane. Part Number: NI SCXI-1349 and either SH68-68-EPM (NI E Series or mass-terminated NI USB M Series) or SHC68-68-EPM (NI M Series) SCXI-1163R SCXI-1190 Note Some switch controllers, like the NI USB-1357/1358/1359, can connect an NI SCXI switch module directly to a computer. Combining this 2-slot HVAB Adaptor with (2) 1-slot Adaptor creates an SCXI-1357. Rate the SCXI-1357. The PXI-1011 has an integrated high-voltage backplane. SCXI-1129. 1553. . The following figure represents the front view of a 2-slot backplane adapter/controller. 2. In Stock Ships Today: SCXI-1362:multiplexer/matrix modules. Fast Quotes & Shipping. The cable assembly connects to the front-end signal conditioning SXCI. Abstract: No abstract text availablemultiplexer/matrix modules. Each cable adaptor has a 50-pin male breakout connector for attaching additional DAQ devices. The device is equipped with electromechanical, latching, and nonlatching relay types. This model implements an advanced switching system, which is based on SCXI technology and does not need any other software. Combining this 1-slot HVAB Adaptor with another 1-slot Adaptor creates and an SCXI-1359 2-slot HCAB create an SCXI-1357. You can also use this cable to cascade digital control signals between multiple SCXI chassis. ni scxiスイッチモジュールにはni-switch 計測器ドライバ が同梱されており、このドライバはデバイスのプログラミングに使用します。 このドキュメントには、NI スイッチモジュールのプログラミングにも使用できるNI-SCXI-1357 Controller module SCXI-1357 Controller module Module Clips Drive controller servo motor Contact: Mr. The SCXI-1358 is identical to the SCXI-1357, except it is for a 12-slot SCXI chassis. Combining this 2-slot HVAB Adaptor with (2) 1-slot Adaptor creates an SCXI-1357. arincarinc & 1553 . This enables the SCXI system to be located closer to the sensors and transducers. This enables the SCXI system to be located closer to the sensors and transducers. Triggering for Switches (NI 4060 only)terminal blocks (SCXI 1303 and SCXI 1325), signal conditioning hardware (SCXI 1102), and a digital to analog conversion module (SCXI 1124). arincarinc & 1553 . arincSCXI-1314 Printed Circuit Board Diagram The following illustration shows the locations of the SCA and SCB resistors, the quarter-bridge resistors, and channels 0 through 7 of the SCXI-1314 terminal block. 1553. Particle Sizers / CountersSite Search Results. Fraction Collectors / Autosamplers / Autoinjectors / Autowashers / Synthesizers. Speak to a sales representative for pricing & lead time: Phone:National Instruments NI SCXI 1359. 4-Slot, High-Voltage SCXI Connector. C. This controller is especially useful in production tests where you need an SCXI controller to route signals through a switch to existing data acquisition devices. The output signal can easily be routed to an NI 4070 DMM to be measured. Call. The National Instruments 1357,1358,1359 and SCXI-1362 communication adapters and high-voltage backplane assemblies provide several options for communication with and expansion ofthe functionality ofyour SCXI switch chassis. 4-Slot, High-Voltage SCXI Connector—The SCXI-1357 is a high-voltage analog bus (HVAB) adapter. Each cable adaptor has a 50-pin male breakout connector for attaching additional DAQ devices. For a completely plug-and-play solution that does not. The USB-1357 is manufactured. 1553. Other slot adapters are sold separately. Shakers / Stirrers / Mixersarinc & 1553 . This Backplane Assembly is used for matrix expansion or signal routing between SCXI modules. The. 18 185434-0R18SCXI-1127/1128, SCXI-116X family, and SCXI-1190/1191. The NI 1357 kit (4 slots) consists of the following components: NI USB-1359 or NI SCXI-1359 NI SCXI-1359 One 8-pin HVAB plug SH9MD-9MD cable (SCXI kits) or USB cable (USB kits) Figure 1 illustrates the components of the NI 1357/1358/1359 kit. The PXI-1011 includes an embedded high-voltage analog bus (HVAB); therefore. Part Number: 776572-93 Description :. NI SCXI cable assemblies connect a DAQ device to the SCXI system. Alternatively, a switch controller installed in the rightmost PXI slot of an NI PXI-1010/1011/1050/1052 chassis does not require any additional cables or adapters to connect to the switch module. The SCXI-1357, crafted by National Instruments, is a High Voltage Backplane Adapter. Alternatively, a switch controller installed in the. 1553. NI 9269 Getting Started Guide National. 1 Data Acquisi tion System Set-upSCXI ™ SCXI-1129 User Manual 256 Crosspoint High-Density Matrix SCXI-1129 User Manual February 2001 Edition Part Number 322740A-01 Support Worldwide Technical Support and Product Information ni. NI SCXI switch modules require a dedicated switch controller, often cabled to the switch module using an adapter kit. For SCXI systems operating in multiplexed mode, you need onlyNational Instruments offers switches with scanning capabilities. In most applications, this is the most convenient grounding option. Homepage;National Instruments SCXI-1341 Adapter BoardThis unit has a broken connector. This document explains the different scanning options, hardware setup, and programming techniques for scanning several modules. The SCXI-1362 works much like the SCXI. ¥Ifyou are using a PXI-1010 or an SCXI chassis use an SCXI-1357 or SCXI-1359 kit. NI SCXI-1357/1358/1359 kit, proceed directly to step 4 to create a new SCXI chassis. flathead screwdriver Long-nose pliers Wire cutter Wire insulation stripper Safety Information Cautions Do not operate the device in an explosive atmosphere or where there may be flammable gases or fumes. Combining this 1-slot HVAB Adaptor with another 1-slot Adaptor creates and an SCXI-1359 2-slot HCAB create an SCXI-1357. This model can easily control many switching modules, which includes the following: the SCXI-1102/B/C, SCXI-1124, the SCXI-116X family, the SCXI 1190/1191, and the SCXI. The AUX connector is meant to be used when a DMM is controlling a switch in an SCXI Chassis, like out SCXI-1130. The SCXI-1357 can be used with and AUX cable to let the DMM control the SCXI chassis and send the trigger to the. arinc & 1553 . This enables the SCXI system to be located closer to the sensors and transducers. You can also route these signals to the NI 4060 or PXI-4070 FlexDMM for measurements. HV8 to HV8 Use this cable to cascade high-voltage 1 185437-01 Cable (Figure 11) analog buses between two SCXI chassis. National Instruments offers switches with scanning capabilities. The high voltage backplane has the following speci fications : SCXI-1357 consists of a 4-slot high-voltage backplane, two cables for routing analog and digital signals to an external scanning DMM, and two analog bus plugs for connecting the backplane components. The NI USB-1357 is designed and manufactured by National Instruments. BAN4 to LV6 cable Use this cable to connect theTB-2605 0. The National Instruments 1357,1358,1359 and SCXI-1362 communication adapters and high-voltage backplane assemblies provide several options for communication with and expansion ofthe functionality ofyour SCXI switch chassis. Manufacturer. The National Instruments SCXI-1346 is perfect for multichassis systems. Alternatively, a switch controller installed in the rightmost PXI slot of anThe SCXI-1127,SCXI-1128 and SCXI-1129 have the capability to route analog signals to their rear connector. a switch controller to an SCXI switch module; the USB kit connects a. Lai Wechat:17750010683 Whats app:+86 17750010683 Skype:+86 17750010683 QQ: 3221366881 3221366881@qq. Other slot adapters are sold separately. View It Live with InstraViewThe USB-1357 is a high-voltage SCXI Plug-and-Play Backplane for USB. National Instruments PCI-4021 Switch Controller Manuals, Datasheets, Drivers, LinksThe SCXI-1359 is the 2-slot HVAB Adapter for SCXI chassis. 1553. arincarinc & 1553 . These are made specifically for the four slot chassis in the DAQ system. Finally, there is the SCXI-1355, which is a shielded cable assembly with cable lengths to. 8 x 7. com for information on these kits. Figure 1. The NI SCXI-1129 has Free Ground Shipping and a 1-3 Year Warranty. Assembling the system requires the use of the SCXI 1349 shielded cable assembly and the SCXI 1357 high voltage backplane. View sales history, tax history, home value estimates, and overhead views. Page 1 SCXI-1336. Other slot adapters are sold separately. The three available backplane kits are: SCXI-1357, SCXI-1358, and or SCXI-1359. Fraction Collectors / Autosamplers / Autoinjectors / Autowashers / Synthesizers. The NI 4021 is compatible with the SCXI-1357/1358 high-voltage backplane adapters and the SCXI-1362 low-voltage adapter. If necessary, power on the chassis. Single module information can be found in the NI. Choose one of the following options to configure your device in MAX: • For devices cabled to an NI SCXI-1357/1358/1359 kit, proceed to . 1553. 51. 1553. They consist of high-quality,low-noise cables,which guarantee reliable communication and signal integrity at up to 10 m. National Instruments offers switches with scanning capabilities. 1553. . National Instruments offers switches with scanning capabilities. com ¥ ni. National Instruments USB-1357 SCXI Plug-and-Play Backplane for USBThis does not include any other equipment or cabling. Recorders / DataloggersSite Search Results. 3. Also for: Sb-gpib/tnt. 57 to 0. Alternatively, a switch controller installed in the rightmost PXI slot of anAll Other NI SCXI. Combining this 2-slot HVAB Adaptor with (2) 1-slot Adaptor creates an SCXI-1357. are not included with this equipment unless listed in the above stock item description. Note When connecting your signals to the SCXI-1327, follow the labeling on the SCXI-1327 for the appropriate module, as indicated in Figure 2. The SCXI-1357 consists of (2) 1-slot HVAB Adapters and (1) SCXI. Find local businesses, view maps and get driving directions in Google Maps. The cable assembly connects to the front-end signal conditioning SXCI. arincSCXI-1128, or SCXI-1129, you can measure thousands of channels, consisting of voltages, thermocouples, RTDs, thermistors, and current loops, and keep a firm control on the cost of your system. Some SCXI switches can route analog signals to their rear connector, and you can use the SCXI-1357 to share these signals among several modules in compatible chassis. Pin 9 on HVAB adapter NI SCXI-1357/1358/1359 connected to the module in Slot 12: Refer to the niSwitch Configure Scan Trigger VI or the niSwitch_ConfigureScanTrigger function for descriptions and values of the trigger inputs and scan advanced outputs. Figure 1. To add more National Instruments 185003A-01 1-Slot High Voltage Backplane AdaptorThe 185003A-01 is the 1-slot HVAB Adapter for SCXI chassis. 1-slot adapters are sold separately. The high voltage backplane has the following specifications:This enables the SCXI system to be located closer to the sensors and transducers. Add to cart. tor backshell kit to ensure that the terminals are not accessible. Embedded & Industrial . If you want to share these signals among several modules, you need to use the high-voltage analog bus (HVAB) adapter (like the SCXI-1357 and SCXI-1358). Particle Sizers / Countersabstract: pci-4060 pxi-4060 scxi-1357 4060 pxi-2501 pxi-2503 scxi-1127 scxi-1128 scxi-1129 Text: 4060 hardware, P -1 probe set, NI-DMM, DMM Soft Front Panel, and calibration certificate. The AUX connector is meant to be used when a DMM is controlling a switch in an SCXI Chassis, like out SCXI-1130. The cable assembly connects to the front-end signal conditioning SXCI. House located at 1357 Rockland Ave, Victoria, BC V8S 1V7. In Stock Ships Today: SCXI-1361: The SCXI-1361 is a National Instruments Rear Filler Panel with a Features Multiple SCXI Cables / Adapters . 1553. The National Instruments PCI-4021 provides all the vital SCXI communication lines. SCXI-1349 National Instruments SCXI-1349 Adapter Board from National Instruments | Buy Today from Artisan. Fieldpoint / CompactFieldpointarinc & 1553 . Each cable adaptor has a 50-pin male breakout connector for attaching additional DAQ devices. 4-Slot, High-Voltage SCXI Connector. This controller is especially useful in production tests where you need an SCXI controller to route signals through a switch to existing data acquisition devices. National Instruments SH9MD-AUX HVAB Cable (1 Meter)Similar to the SH9MD-9MD. The probe sets meet IEC 1010 safety requirements and permit direct probing of circuits and cables. Single module information can be found in the NI. Refer to page 507 for more information on switch cabling. Readers should have a basic knowledge of single module scanning hardware setup and programming. Combining this 2-slot HVAB Adaptor with (2) 1-slot Adaptor creates an SCXI-1357. Part Numbers: 776576-61, 181625D-01, 181625-01 Rev. arinc & 1553 . The USB-1357 is manufactured with the part number 776576-571. The SCXI-1357 can be used with and AUX cable to let the DMM control the SCXI chassis and send the trigger to the SCXI switch. Embedded & Industrial . Embedded & Industrial . arincPXI-2503, SCXI-1127, SCXI-1128, or SCXI-1129, you can measure thousands of channels, consisting of voltages, thermocouples, RTDs, thermistors, and current loops, and keep a firm control on the cost of your system. Single module information can be found in the NI. This enables the SCXI system to be located closer to the sensors and transducers. Find the National Instruments SCXI-1000 at our website: Click HERE. Each cable assembly includes a cable and one or more SCXI cable adapters. National Instruments SCXI-1129 with electromechanical relays. Readers should have a basic knowledge of single module scanning hardware setup and programming. are not included with this equipment unless listed in the above stock item description. Shakers / Stirrers / MixersThe NI 1357 kit (4 slots) consists of the following components: † NI USB-1359 or NI SCXI-1359 † NI SCXI-1359 † One 8-pin HVAB plug † SH9MD-9MD cable (SCXI kits) or USB cable (USB kits) Figure 1 illustrates the components of the NI 1357/1358/1359 kit. Associated Part Numbers: 184366-01, 184366C-01, 184366D-01, 184366E-01, 776572-27. NI SCXI-1600 when used with NI SCXI-1349 and either SH68-68-EPM (NI E Series or mass-terminated NI USB M Series) or SHC68-68-EPM (NI M Series) SCXI-1163R SCXI-1190 Note Some switch controllers, like the NI USB-1357/1358/1359, can connect an NI SCXI switch module directly to a computer. For example, in a 2-wire 32×1 multiplexer, two NI SCXI-1127/1128 modules can create a 64×1 2-wire multiplexer with an NI SCXI-1359. 178, 0. Alternatively, a switch controller installed in the rightmost PXI slot of anSummary of Contents for National Instruments SCXI-1336. HV8 to HV8 Use this cable to cascade high-voltage 1 185437-01 Cable (Figure 11) analog buses between two SCXI chassis. Fig. The NI PXI-4021 requires no extra programming other than the NI-SWITCH controller it receives with the National Instruments switches. In Stock. If you are using NI-DAQmx to configure SCXI switch modules cabled to an NI USB-1357/1358/1359 kit and the NI USB-1359 is auto-detected and the chassis is auto-created in MAX, expand the NI-DAQmx Devices tab, right-click the chassis, and choose Properties. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. Alternatively, a switch controller installed in the. National Instruments 185436A-01 8-Position High Voltage Analog Bus (HVAB) Backplane Adapter | Easy Click-Quote-Buy Today! Fast Shipping. SCXI-1317 Circuit Parts Location Diagram 6. Components of the NI 1357/1358/1359 Controller/Adapter Kit Installing the KitTengo un NI 4070 digital multi-meter(DMM) con 2 chassis controlando módulos Switch. If you want to share these signals among several modules, you need to use the high-voltage analog bus (HVAB) adapter (like the SCXI-1357 and SCXI-1358). The SCXI-1358 is identical to the SCXI-1357, except it is for a 12-slot SCXI chassis. These controllers are compatible with the SCXI-1357/1358 high-voltage backplane adapters and the SCXI-1362 low-voltage adapter. 1553. arinc & 1553 . The high voltage backplane has the following specifications:Assembling the system requires the use of the SCXI 1349 shielded cable assembly and the SCXI 1357 high-voltage backplane. The 9 Pin DIN connectors for the SH9MD-AUX cable are circled in the Figure 5. Fraction Collectors / Autosamplers / Autoinjectors / Autowashers / Synthesizers. Single module information can be found in the NI. This unit ships in the opened National Instruments box. The NI SCXI-1357 is manufactured with part numbers 776575-57, 776575-571 , 776575-572,. The SCXI-1127 weighs 1 lb, and has the dimensions: 1. com National Instruments Corporate Headquarters 11500 North Mopac Expressway Austin, Texas 78759-3504 USA Tel: 512 794 0100 Worldwide Offices Australia 03 9879 5166,. ; Page 2 Thailand 662 992 7519, United Kingdom 44 0 1635 523545 For further support information, refer to the Technical Support and Professional Services. National Instruments manufactured this High Voltage Backplane. This enables the SCXI system to be located closer to the sensors and transducers. 229 ASTM D374 Hardness (Shore A) 85 85 , (°C/W) 0. for Solaris. Your NI SCXI switch module ships with the NI-SWITCH instrument driver, which you can use to program the device. NI SCXI-1357/1358/1359 kit, proceed directly to step 4 to create a new SCXI chassis. The SCXI-1358 is identical to the SCXI-1357, except it is for a 12-slot SCXI chassis. Single module information can be found in the NI. This home was built in 1983 and last sold on. Tengo un NI 4070 digital multi-meter(DMM) con 2 chassis controlando módulos Switch. National Instruments SCXI-1128 Matrix/Multiplexer Switch Module- 9 W maximum switching power. Alternatively, a switch controller installed in the rightmost PXI slot of anThe NI SCXI-1360 is a front filler panel, which can be used for covering the slot’s front side. ¿Podría usar un sólo 4070 (o cualquier otro DMM) para controlar los switches en ambos chassis?arinc & 1553 . Visit ni. com DAQmx USB was unexpectedly terminated while. This cable is included in the SCXI-1357 and SCXI-1358 multichassis expansion kits. This document describes the components, installation, and configuration of the National Instruments SCXI-1357/1358/1359 and the NI USB-1357/1358/1359 controller/adapter. 1553. NI SCXI-1600 when used with NI SCXI-1349 and either SH68-68-EPM (NI E Series or mass-terminated NI USB M Series) or SHC68-68-EPM (NI M Series) SCXI-1163R SCXI-1190 Note Some switch controllers, like the NI USB-1357/1358/1359, can connect an NI SCXI switch module directly to a computer. Control Systems / PLCNI SCXI-1357/1358/1359 kit, proceed directly to step 4 to create a new SCXI chassis. PXI-2503, SCXI-1127, SCXI-1128, or SCXI-1129, you can measure thousands of channels, consisting of voltages, thermocouples, RTDs,. National Instruments SCXI-1359 2-Slot High Voltage Backplane Adaptor. The SCXI kit connects. Price: US $249. Readers should have a basic knowledge of single module scanning hardware setup and programming. The high voltage backplane has the following specifications:. Each cable assembly includes a cable and one or more SCXI cable adapters. Single module information can be found in the NI. This enables the SCXI system to be located closer to the sensors and transducers. Figure 1. 79 N⋅ m (5 to 7 lb - in. Ships in 5-10 Days. The SCXI-1362 works much like the SCXI. arinc & 1553 . SCXI-1327 Parts Locator Diagram 4. This adapter enables the user to expand the high-voltage analog bus. Contact us. The SCXI-1129 by National Instruments is In Stock & Ready to Ship. Other Industrial. This controller is especially useful in production tests where you need an SCXI controller to route signals through a switch to existing data acquisition devices. HV8 to HV8 Use this cable to cascade high-voltage 1 185437-01 Cable (Figure 11) analog buses between two SCXI chassis. The National Instruments PXI-4021 (Part Number: 778277-01) switching controllers permit the control of SCXI-based switching frameworks from a PCI or PXI slot. Fast Quotes & Shipping. SCXI-1357 National Instruments, NI, SCXI-1357 National Instruments SCXI-1357 National Instruments Module Clips Drive controller servo motor Contact: Mr. If you are using NI-DAQmx to configure SCXI switch modules cabled to an NI USB-1357/1358/1359 kit and the NI USB-1359 is auto-detected and the chassis is auto-created in MAX, expand the NI-DAQmx Devices tab, right-click the chassis, and choose Properties. DMM,and analog bus plugs for connecting the backplane components. This enables the SCXI system to be located closer to the sensors and transducers. Alternatively, a switch controller installed in the rightmost PXI slot of anThese Controllers are attuned with high-voltage backplane adapters like the SCXI-1357/1358. The SCXI-1358 is identical to the SCXI-1357, except it is for a 12-slot SCXI chassis. National Instruments offers switches with scanning capabilities. Figure 1. arincNI SCXI-1600 when used with NI SCXI-1349 and either SH68-68-EPM (NI E Series or mass-terminated NI USB M Series) or SHC68-68-EPM (NI M Series) SCXI-1163R SCXI-1190 Note Some switch controllers, like the NI USB-1357/1358/1359, can connect an NI SCXI switch module directly to a computer. 2 installation manual online. Refer to page 498 for more information on switch cabling. One SCXI cable assembly per SCXI chassis is needed to operate the SCXI system in multiplexed mode. 2 controller pdf manual download. Fraction Collectors / Autosamplers / Autoinjectors / Autowashers / Synthesizers. This cable is included in the SCXI-1357 and SCXI-1358 multichassis expansion kits. Page 2 SCXI ™ SCXI-1129 User Manual 256 Crosspoint High-Density Matrix SCXI-1129 User Manual February 2001 Edition Part Number 322740A-01. One SCXI cable assembly per SCXI chassis is needed to operate the SCXI system in multiplexed mode. 2Requires same cabling as SCXI Chassis. Connect the DAQ device to a different computer or PXI controller slot, module or USB port. SCXI-1163R SCXI-1190 Note Some switch controllers, like the NI USB-1357/1358/1359, can connect an NI SCXI switch module directly to a computer. The NI SCXI-1357 is manufactured with part numbers 776575-57, 776575-571 , 776575-572, and 185008B-01. 1. following kits: SCXI-1357, SCXI-1358, SCXI-1359, and SCXI-1362. com Figure 4. Part Number: 776575-57, 185006A-01, 185006B-01, 185008A-01, 185008B-01 National Instruments 181625-01 Rear Filler Panel for SCXI-1361. This document describes the components, installation, and configuration. 若您的switch模块不能够被连接到scxi-1357,那么您可以采用scxi-1362适配工具来连接您的dmm。scxi-1362的工作方式与scxi-1357很像,也采用aux i/o端口来连接dmm的数字信号。能够与scxi-1362配合使用的switch包括: scxi-1160 ; scxi-1161 ; scxi-1163r ; scxi-1190 ; scxi-1191 ; scxi-1192 National Instruments SCXI-1349 Adapter Board. For , 51/2 Digit Multimeters 51/2 Digit Multimeters NI 4050, NI 4060 · 51/2-digits · 5 measurement , Measurement Studio for Visual C+ · NI PCMCIA-4050 · NI. Fig. 185436A-01 National Instruments 185436A-01 8-Position High Voltage Analog Bus (HVAB) Backplane Adapter from National Instruments | Buy Today from Artisan. Switch Module supports the analog bus with a specific adapter, the high-voltage analog bus backplane adapter in the SCXI-1357/1358 kit, at the back of the module. 1553. It ships as photoed. The NI 4021 is compatible with the SCXI-1357/1358 high-voltage backplane adapters and the SCXI-1362 low-voltage adapter. This document contains information about the NI-DAQmx driver software, which you can also use to program NI switch modules. This product is available in the market with multiple part numbers like 776575-57, 776575. The NI SCXI-1127/1128/1129/1175 modules have the capability to route analog signals to their rear connector. The NI 4021 is compatible with the SCXI-1357/1358 high-voltage backplane adapters and the SCXI-1362 low-voltage adapter. ranges, the NI 4050 and NI 4060 DMMs measure the AC-coupled. One SCXI cable assembly per SCXI chassis is needed to operate the SCXI system in multiplexed mode. Combining this 1-slot HVAB Adaptor with another 1-slot Adaptor creates and an SCXI-1359 2-slot HCAB create an SCXI-1357. The NI USB-1357 is used with the NI driver tools. No Interest if paid in full in 6 mo on $99+ with PayPal Credit*. • For devices cabled to an NI USB-357/1358/1359 kit. Each cable adaptor has a 50-pin male breakout connector for attaching additional DAQ devices. This cable is included in the SCXI-1357 and SCXI-1358 multichassis expansion kits. MXI / MXI-2 / MXI-3 / MXI-4. Includes: Adapter and installation guide. • Ground the negative lead of the thermocouple inside the SCXI-1300 terminal block, by connecting CH– to CHSGND as shown in Figure 4. BAN4 to LV6 cable Use this cable to connect theTB-2605 0. Each cable adaptor has a 50-pin male breakout connector for attaching additional DAQ devices. View online (12 pages) or download PDF (1 MB) National Instruments SCXI NI 1359, SCXI NI 1358 Installation manual • SCXI NI 1359, SCXI NI 1358 PDF manual download and more National Instruments online manualsThe SCXI-1357 is a National Instruments Adapter Board with a Features Multiple SCXI Cables / Adapters . (SCXI-1001) chassis, the back of SCXI-1127 in slot4(or slot12 for SCXI-1001) • Voltage cable HV8 toBan4, connects the HI/LO channel terminals of the DMM with the HVAB, • Communications Trigger cable SH9MD-9MD connects the AUX I/O connector of the DMMSCXI-1127. Traditional NI-DAQ (Legacy) NI-DAQmx — NI-DAQmx Devices. 1 shows a pi cture of the actual system. 1553. This enables the SCXI system to be located closer to the sensors and transducers. Alternatively, a switch controller installed in the rightmost PXI slot of an. Readers should have a basic knowledge of single module scanning hardware setup and programming. a. are not included with this equipment unless listed in the above stock item description. This controller is especially useful in production tests where you need an SCXI controller to route signals through a switch to existing data acquisition devices. SCXI-1127/1128, SCXI-116X family, and SCXI-1190/1191. Each cable adaptor has a 50-pin male breakout. Alternatively, a switch controller installed in the rightmost PXI slot of an NI PXI-1010/1011/1050/1052 chassis does not require any additional cables or adapters to connect to the switch module. SCXI-1127/1128, SCXI-116X family, and SCXI-1190/1191. NI SCXI-1600 when used with NI SCXI-1349 and either SH68-68-EPM (NI E Series or mass-terminated NI USB M Series) or SHC68-68-EPM (NI M Series) SCXI-1163R SCXI-1190 Note Some switch controllers, like the NI USB-1357/1358/1359, can connect an NI SCXI switch module directly to a computer. Fraction Collectors / Autosamplers / Autoinjectors / Autowashers / Synthesizers. This controller is especially useful in production tests where you need an SCXI controller to route signals through a switch to existing data acquisition devices. Each cable assembly includes a cable and one or more SCXI cable adapters. Your NI SCXI switch module ships with the NI-SWITCH instrument driver, which you can use to program the device. Proceeding in this direction requires you to create an SCXI controller out of the PCI-GPIB board (or whatever hardware is hot-wired to the SH9MD-AUX cable). Part Numbers: 776575-571, 776575-572. If you are using NI-DAQmx to configure SCXI switch modules cabled to an NI USB-1357/1358/1359 kit and the NI USB-1359 is auto-detected and the chassis is auto-created in MAX, expand the NI-DAQmx Devices tab, right-click the chassis, and choose Properties. The SCXI kit connects a switch controller to an SCXI switch module; the USB kit connects a computer to an SCXI switch module. Fieldpoint / CompactFieldpointView and Download National Instruments NI-488. If you are using NI-DAQmx to configure SCXI switch modules cabled to an NI USB-1357/1358/1359 kit and the NI USB-1359 is auto-detected and the chassis is auto-created in MAX, expand the NI-DAQmx Devices tab, right-click the chassis, and choose Properties. Finally, there is the SCXI-1355, which is a shielded cable assembly with cable lengths to 10 m. Each cable assembly includes a cable and one or more SCXI cable adapters. Fraction Collectors / Autosamplers / Autoinjectors / Autowashers / Synthesizers. Play any role in anyway if model of chassis is same . BAN4 to LV6 cable Use this cable to connect theTB-2605 0. Components of the NI 1357/1358/1359 Controller/Adapter Kit Installing the Kit NI offers SCXI and USB versions of the 1357, 1358, and 1359 backplane adapter kits that can connect from two to eight SCXI switches. National Instruments will, at its option, repair or replace equipment that proves to be defective duringtheterminal blocks (SCXI 1303 and SCXI 1325), signal conditioning hardware (SCXI 1102), and a digital to analog conversion module (SCXI 1124). Menu. arinc4-Slot, High-Voltage SCXI Connector. This cable assembly routes signals from the digitizer to subsequent SCXI chassis. The cable assembly connects to the front-end signal conditioning SXCI. The NI 4021 is compatible with the SCXI-1357/1358 high-voltage backplane adapters and the SCXI-1362 low-voltage adapter. The SCXI-1358 is identical to the SCXI-1357, except it is for a 12-slot SCXI chassis. These Controllers are also compatible with the low-voltage adapters like the SCXI-1362. The SCXI-1357 consists ofa 4-slot high-voltage backplane, two cables for routing analog and digital signals to an external scanning DMM,and analog bus plugs for connecting the backpla ne components. multiplexer/matrix modules. You can add insulation or padding if necessary. computer to an SCXI switch module. This Switch Controller is less expensive than other models and provides suitable control elucidation for switching modules. comDrives / Motion / Motor Control / Positioning. National Instruments offers switches with scanning capabilities. 300V MAX HV ANALOG BUS 300V MAX HV ANALOG BUS 300V MAX HV ANALOG BUS 2 4 300V MAX HV ANALOG BUS 4-Slot, High-Voltage SCXI Connector. ni 1357 キット(4 スロット)は次の部品で構成されてます。 • ni usb-1359 またはni scxi-1359 • ni scxi-1359 •8ピンhvab プラグ(1) • sh9md-9md ケーブル(scxi キット)またはusb ケーブル (usb キット) 図1 は、ni 1357/1358/1359 キットに含まれる部品を示します。following kits: SCXI-1357, SCXI-1358, SCXI-1359, and SCXI-1362. OtherTo handle large channel counts, you can expand the size of the multiplexer with additional SCXI-1127/1128 modules. Refer to page 498 for more information on switch cabling. The 2,600 sq. Alternatively, a switch controller installed in the rightmost PXI slot of an The SCXI-1127,SCXI-1128 and SCXI-1129 have the capability to route analog signals to their rear connector. Proceedings of the 2003 American Society for Engineering Education Annual Conference & Exposition Copyright Ó 2003, American Society for Engine ering EducationNational Instruments PXI-4021 Switch ControllerPart Number: 184793G-02, 778277-01NI SCXI-1349 and either SH68-68-EPM (NI E Series or mass-terminated NI USB M Series) or SHC68-68-EPM (NI M Series) SCXI-1163R SCXI-1190 Note Some switch controllers, like the NI USB-1357/1358/1359, can connect an NI SCXI switch module directly to a computer. Figure 5: Rear view of SCXI backplanes with 9-pin Din Connectors SCXI switches require a backplane to connect the SH9MD-AUX cable for controlling or triggering. This does not include any other equipment or cabling. Fraction Collectors / Autosamplers / Autoinjectors / Autowashers / Synthesizers. National Instruments 185003A-01 1-Slot High Voltage Backplane AdaptorThis unit is sealed in the manufacturer's bag. Fieldpoint / CompactFieldpointThe NI 1357 kit (4 slots) consists of the following components: † NI USB-1359 or NI SCXI-1359 † NI SCXI-1359 † One 8-pin HVAB plug † SH9MD-9MD cable (SCXI kits) or USB cable (USB kits) Figure 1 illustrates the components of the NI 1357/1358/1359 kit. The SCXI-1359 is the 2-slot HVAB Adapter for SCXI chassis. Expand the NI-DAQmx Devices tab. Your NI SCXI switch module ships with the NI-SWITCH instrument driver, which you can use to program the device. arincUsing the SCXI-1127 Switch Module National Instruments pg. Run the signal wires through the strain-relief opening. National Instruments SCXI-1357 4-Slot High Voltage Backplane Adaptor.